High quality temperature controlled battery short circuit tester
Application
Battery short circuit testing machine
The short-circuit tester adopts PLC automatic control to simulate the external short circuit of the battery. It meets the requirements of UL1642, UN38.3, IEC62133, GB/、GB/T18287, GB/T 31241-2014, and other standards. The tester records changes in battery voltage, current, and surface temperature. The entire circuit (including circuit breaker, wires, and connecting devices) must have a resistance of 80±20mΩ, and each circuit is capable of withstanding short-circuit currents with a peak value of 1000A. The short circuit stop mode can be selected: 1. short circuit time; 2. battery surface temperature.
Auxiliary Structure
| Inner box size | 500(W)×500(D)×600(H)mm | 
| control method | PLC touch screen control + wireless remote control short circuit action command | 
| temperature range | RT+10°C~85°C (adjustable) | 
| Temperature fluctuation | ±0.5℃ | 
| temperature deviation | ±2℃ | 
| operating voltage | AC 220V 50Hz~ 60Hz | 
| impulse voltage | AC 1kv/1.2-50μs 1min | 
| Maximum short-circuit current | 1000A (Maximum current can be specified to order) | 
| DC Response Time | ≤5μs | 
| Device internal resistance | 80mΩ±20mΩ | 
| movement time | Suction time/release time ≯30ms | 
| Motion Characteristics | Cold Suction Voltage ≯66%Us | 
| Cold Release Voltage | ≯30%Us, ≮5%Us | 
| Inner box material | Stainless steel plate 1.2mm thick with Teflon, corrosion-resistant and flame-retardant. | 
| Outer case material | A3 cold plate lacquered 1.5 mm thick | 
| viewing window | 250x200mm two-layer vacuum toughened glass viewing window with explosion-proof grill | 
| drain | The rear side of the box is equipped with a pressure relief device and exhaust air vents | 
| box door | Single door, left opening | 
| Box door switch | A threshold switch that switches off when opened ensures that there is no inadvertent operation, guaranteeing the safety of personnel. | 
| test hole | There is a φ50 mm test hole on the left or right side of the unit. Convenient for placing various temperature, voltage and current collection lines. | 
| caster | Four universal castors underneath the machine for free movement. | 
| Voltage Acquisition | Voltage range: 0~100V Acquisition rate: 100ms Number of channels: 1 channel Accuracy: ±0.8% F.S (0~100V) | 
| Current Acquisition | Current range: 0~1000A DCA Acquisition rate: 100ms Number of channels: 1 channel Accuracy: ±0.5%F.S | 
| Battery Temperature Acquisition | Temperature range: 0℃~1000℃ Acquisition rate: 100ms Number of channels: 1 channel Accuracy: ±2℃ | 
| Short circuit contactor life | 300,000 times | 
| Data export | With USB data export port, you can export the report, view the test data and curves | 
| power supply | 3KW | 
| Using the power supply | 220V 50HZ | 
| Outer box size | Approx. 750*800*1800mm (W*D*H) subject to actual size | 
| Equipment weight | Approx. 200KG | 
| Optional | Manual and automatic fire extinguishing function | 
 
				













 
             
             
             
            